Description
- Working voltage: AC 220V/110V 50/60Hz ±10%
- Working current: please note that the equipment can not work long time under the state of operation when its current is greater than the rated current.
- Working environment: the temperature is 0℃- 40 ℃
- Working humidity: 40%- 90%
- Working frequency: from 17khz to 135khz
- Time : 0-59 minutes and 59 seconds
Notes:
- The ultrasonic generator can’t power on under no-load condition
- After installed, we can not power on until lay cleaning fluid
- Ultrasonic transducer has two lugs.The positive one lay in the middle of two pieces of ceramic.The native one near lower metal column. Please do not make wrong when wiring.
- The larger side with screw hole in ceramic transducer which has a function of vibration,can be stuck in the bottom of cleaning machine. And please make sure the cleaning machine is safely grounding.
- The ceramic transducer should be pasted in the bottom of cleaning machine using transducer specialized glue or use AB glue stick. but the effect is a bit poor, or use epoxy resin with proportion of 10:4.
- The working circuit board voltage is 600V. The voltage output to the transducer is 1100 v.Please ensure the cleaning machine is safely grounding. Please make sure leakage protection switch assembled on the power supply in order to ensure safety.




Chris L –
Jessie has been providing excellent services whenever asking for product information and support, especially when product is facing some technical problem. There were some information inaccuracy between communication and causing issue to our application but Jessie is able to compromise to resolve the issue. I would like to thank Jessie for her well support.
John –
Excellent Product, Price, and Service. I was not prepared for such fast shipping. Thanks BJUltrasonic